Scroll

Position Compensation

External Reference Data
No.
Character
Data name
Set/Get
Data range
0
JG
judge
Judge
Get only
0: No judgement(unmeasured)
1: Judgement result OK
-1: Judgement result NG
-10: Error(image format mismatch)
-11: Error(unregistered model)
-12: Error(insufficient memory)
-20: Error(other errors)
5
DX
moveX
Scroll X
Get only
-99,999.9999 to 99,999.9999
6
DY
moveY
Scroll Y
Get only
-99,999.9999 to 99,999.9999
7
DT
moveAngl
Scroll θ
Get only
-999.9999 to 999.9999
8
X
measPosX
Position X
Get only
0 to 99,999.9999
9
Y
measPosY
Position Y
Get only
0 to 99,999.9999
10
TH
measAngl
Measurement θ
Get only
-360 to 360
11
SX
stdPosX
Reference X
Get only
-99,999.9999 to 99,999.9999
12
SY
stdPosY
Reference Y
Get only
-99,999.9999 to 99,999.9999
13
ST
stdAngl
Reference θ
Get only
-999.9999 to 999.9999
120
compensation
Interpolation
Set/Get
0:None
1:Bilinear
121
setupMode
Method
Set/Get
0: 1 unit scroll
1: 2 unit scroll
2: Expression
3: Reset scroll
122
targetImage
Scroll target
Set/Get
0: Camera image
1: Prev. unit image
123
rotation
With rotation
Set/Get
0: OFF
1: ON
124
setDataRefX
Reference position X
Set/Get
Expression: 256 characters or less
125
setDataRefY
Reference position Y
Set/Get
Expression: 256 characters or less
126
setDataRefAngl
Reference angle
Set/Get
Expression: 256 characters or less
127
setDataPosX
Measurement position X
Set/Get
Expression: 256 characters or less
128
setDataPosY
Measurement position Y
Set/Get
Expression: 256 characters or less
129
setDataAngl
Measurement angle
Set/Get
Expression: 256 characters or less